Search
FAQ- Frequently asked questions

Proof load test

Why is Gunnebo Lifting the only producer in the world that proof load test each Classic and Grabiq component and chain link, when National and International Standards do not require this?

By proof loading each component 2,5 times WLL we can detect faults that other forms of NDT cannot. It provides great peace of mind and confidence to know that all our products released on the market have passed our rigorous tests.